> YAHOPE iCHECK Implant Stability Meter Dental Implant Osseointegration Monitor
Item DescriptionReviews
YAHOPE iCHECK Implant Stability Meter Dental Implant Osseointegration Monitor
Mechanical stability: In the initial stage after implantation, the degree of integration and stabili-ty between the implant and the bone is a purely mechanical phenome-non. Its value shows a decline from high to low during the early period.
Biological stability: The stable, harmonious, and healthy biological integration between the implant and the surrounding tissues is crucial for long-term success. Bio-logical stability is one of the key factors for successful implants. Its value shows an upward trend from low to high in the initial period.
Total stability: The overall stability state formed between the implant and the surround-ing bone and tissues. It encompasses the combination of initial stabilityand biological stability, including bone integration, soft tissue adapta-tion, functional loading, and long-term clinical performance of the im-plant.
Features:
Abandoning the traditional detection method using torque wrenches.
Simplified measurement, more convenient operation. Utilizing tapping technology and an automatic safety system, it is used to examine the early integration of implants.
The product utilizes a tricolor display. The numerical values transition from red to green, indicating a gradual increase in stability.
Technical Specifications:
Accuracy: Display value ±3
Tapping Speed:0.5 sec/1 time
Tapping Strength:<1.0N
Number of Tapping: Taps 2~4 times until the measured value of 1~59. After 60~ 99, the devicetaps 6 times in order to measure the stability.
Using the Device:
Keep the host as close to the horizontal line as possible, within 0 to 30 degrees.
Conduct the test twice, once on the buccal side and once on the lingual side. If the difference between the two measurements is less than 5, take the value from the first measurement. Ifthe difference is greater than 5, attempt a third measurement.
Comparison of methods for measuring implant stability
Torque wrench: For implant placement only. Cumbersome to manipulate, it may adversely affect osseointegration.
Resonance frequency analysis: The equipmentis costly to use, measurements are cumbersome, and it can not be used after the prosthetic restoration is placed.
Damping micromotion analysis: The product features simple operation, precise measurements, and intelligent protective programs.